메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Ah Rang Cho (Kyung Hee University) Hae Kag Lee (Soonchunhyang University) Heung Joon Yoo (Seoul Asan Medical Center) Cheol-Soo Park (Hallym polytechnic university)
저널정보
한국자기학회 Journal of Magnetics Journal of Magnetics Vol.20 No.4
발행연도
2015.12
수록면
381 - 386 (6page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): 450 × 450 ㎟, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: 126 × 126, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to 0 s/㎟, 400 s/㎟, and 1,400 s/㎟, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on isocenter of patient’s table. We used “Image J” as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to 2<SUP>nd</SUP> columns right to left from the core of patient’s table, however, there was a decline in signal intensity and image distortion from the 3<SUP>rd</SUP> columns and they started to decrease rapidly at the 4<SUP>th</SUP> columns. When b-value was 1,400, there was not much difference between the 1st row right to left from the core of patient’s table, however, image distortion started to appear from the 2<SUP>nd</SUP> columns with no change in signal intensity, the signal was getting decreased from the 3<SUP>rd</SUP> columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the 5<SUP>th</SUP> columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient’s table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient’s position.

목차

1. Introduction
2. Subject and Method
3. Results
4. Discussion
5. Conclusions
References

참고문헌 (17)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2016-428-002131505